GE Krautkramer USM 36 Ultrasonic Flaw Detector

GE KRAUTKRAMER USM 36 ULTRASONIC FLAW DETECTOR

The Waygate Technologies Krautkramer USM 36 Ultrasonic Flaw Detector, a Baker Hughes business product (formerly GE Inspection Technologies), is the most versatile ultrasonic flaw detector on the market thanks to its ability to operate in DAC, AWS and DGS modes and with applications including weld inspections, thickness measurements, corrosion measurement, forging inspections and other inspections for difficult materials. The industries where the Waygate Technologies Krautkramer USM 36 proves useful include the automobile, power generation, petrochemical, and aerospace industries.

GE Krautkramer USM 36 Ultrasonic Flaw Detector

GE KRAUTKRAMER USM 36
The Waygate Technologies Krautkramer USM 36 Ultrasonic Flaw Detector, a Baker Hughes business product (formerly GE Inspection Technologies), is the most versatile ultrasonic flaw detector on the market thanks to its ability to operate in DAC, AWS and DGS modes and with applications including weld inspections, thickness measurements, corrosion measurement, forging inspections and other inspections for difficult materials. The industries where the Waygate Technologies Krautkramer USM 36 proves useful include the automobile, power generation, petrochemical, and aerospace industries.

AVAILABLE IN THREE VERSIONS:
The USM 36 Ultrasonic Flaw Detector is offered in three versions to meet the most standard inspection codes. The most advanced version can operate in DAC, AWS and DGS modes, features a powerful square wave pulser for excellent material penetration and can accommodate Waygate’s patented trueDGS probe technology, which offers unrivalled accuracy in sizing of flaws using the DGS method, as well the patented Phantom Echo Detection technology. Another feature included is the 7″ screen that makes viewing A-Scans efficient, with signals being easily viewed even in bright sunlight as well as flexible data storage with removable SD cards or USB ports.

SPECIFICATION GE KRAUTKRAMER USM 36

Display
Display Shift ( Delay) –15 … 3,500 μs
Probe Delay 0 … 1,000 μs
Velocity 250 … 16,000 m/s
PRF Automatically optimized 15 … 2,000 Hz,
3 automatic setting modes: Auto Low,
Auto Med, Auto High, Manual
Display Screen
Size Diagonal 7″
Active Range (W x H) 152.4 × 91.44 mm2
Resolution (W x H) 800 × 480 pixels
Range 4 … 14,108 mm (555“) for longitudinal wave
Connectors
Probe Connectors 2 × LEMO-1 or 2 × BNC
USB Interface USB type B connector
Service Interface LEMO-1B, 8 pin
Pulser
Pulser Mode Spike pulser, optionally: Square-wave pulser
Pulser Voltage (SQ Mode) 120 … 300 V, in steps of 10 V with a tolerance
of 10%
Pulser Falling/Rising Time max. 10 ns
Pulser Width (SQ Mode) 30 … 500 ns, in steps of 10 ns
Pulser Amplitude (Spike Mode) low: 120 V, high: 300 V
Pulser Energy (Spike Mode) low: 30 nS, high: 100 nS
Damping 50 ohms, 1000 ohms
Receiver
Digital Gain Dynamic range 110 dB, adjustable in steps of
0.2 dB
Analog Bandwidth 0.5 … 20 MHz
Equivalent Input Noise <80 nV/√Hz
Filters Broadband: 1-5 MHz / 2, 2.25 MHz / 4, 5 MHz /
10 MHz / 13, 15 MHz
Rectification Positive half-wave, negative half-wave,
full wave, RF signal
Gates
Independent Gates Gates A and B (triggering by gate A),
Gate C (option, triggering by gate A or B)
Measurement Mode Peak, Flank, J-FLANK, FIRST PEAK
Memory
Card Slot SD-card slot for all standard SD-cards
Capacity 8 GB, SD-card
Datasets UGO data structure in ASCII
Reports JPG or BMP format
General
Battery Li-Ion, operating time: 13 hours with full charge
Charging method (standard): internal with power adapter
Charging method (optional): external charger
Charge level: proportional charge level indicator
Power Adapter Universal power supply unit 100 … 240 VAC,
50/60 Hz
Size (W x H x D) 255 × 177 × 100 mm (10” × 7.0” × 3.9”)
Weight 2.2 kg incl. battery
Languages Bulgarian, Chinese, Czech, Dutch, English,
Finnish, French, German, Hungarian, Italian,
Japanese, Norwegian, Polish, Portuguese,
Romanian, Russian, Spanish, Swedish
Damp Heat and Humidity (Storage) EN 60068 Part 2-30
6 cycles: 9 hrs at +25°C up in 3 hrs to +55°C,
9 hrs at +55°C then down to +25°C in 3 hrs, at
93% humidity
Vibration EN 60068 Part 2-6
2g per axis, 5 … 150 Hz, 1 oct/min, 25 cycles
Shocks EN 60068 Part 2-27
1000 cycles per axis, 15 g, 11 ms, half-sine
Enclosure IP66 according to IEC 60529
Operating Temperature –10 … 55°C
Cold Operation –10°C for 16 hrs, 502.5 Procedure II
Heat Operation +55°C for 16 hrs, 501.5 Procedure II
Storage Temperature –20 … +60°C, without battery
Cold Storage –20°C for 72 hrs, 502.5 Procedure I
Heat Storage +70°C for 48 hrs, 501.5 Procedure I
Options
AWS AWS calibration tool, according to AWS D1.1
Structural Welding Code
DAC/JISDAC/CNDAC DAC calibration tool, 16 points, according to EN
1712, EN 1713, EN 1714, ASTM E164, ASME,
ASME III, JIS Z3060, GB11345
TCG: 120 dB dynamic, 110 dB/μs slope
DGS DGS calibration tool, according to: EN 1712, EN
1713, EN 1714, ASTM E164
Data logger Grid file creation
3G Gate C
SWP For pulser parameter optimization,
voltage setting 120 … 300 V in steps of 10 V,
pulse width setting 30 … 500 ns in steps of 10 ns
Phantom-PRF Phantom-PRF for the identification of erroneous
echoes caused by multiple
reflections in low-attenuation materials
BEA Blackwall Echo Attenuation