Used GE Krautkramer USM 35X Ultrasonic Flaw Detector Lemo Version

Used GE Krautkramer USM 35X Ultrasonic Flaw Detector Lemo Version

GE Krautkramer USM 35X

GE Krautkramer USM 35X Synchronics Provides Expert Electronic Repairs For KRAUTKRAMMER ,GE USM 35X – DAC LEMO Ultrasonic Flaw Detector At Synchronics we have the experience in repairing KRAUTKRAMMER ,GE USM 35X – DAC LEMO Ultrasonic Flaw Detector in a timely and cost effective manner. We provide free Quote for KRAUTKRAMMER ,GE USM 35X – DAC LEMO Ultrasonic Flaw Detector sent to us for repair at our works.

GE Krautkramer USM 35X We provide an OEM level of quality service at a competitive, non-OEM price. We have the ability to repair and calibrate many KRAUTKRAMMER units from many different Manufacturers. With our state-of-the-Art technologies and dedicated technicians, our staff is able to ease the pain of any repair service order.

Instrument data supported by the Instrument driver USM 35X: Instrument settings (ultrasonic parameters), A-scans, test results, and Data Recorder file types “Linear” and “Grid”.

Features

  • Straightforward display (as in Windows Explorer) of dataset files of the USM 35X in the AMPLECTOR Instrument Manager with detailed display of the most important instrument settings (ultrasonic parameters), A-scan and measurement values with extended information parameters
  • Straightforward display of Data Recorder files (as in Windows Explorer) with detailed display of Data Recorder type, statistics, as well as instrument settings and notes
  • Display of instrument information (for example software version)
  • Import and export of dataset files
  • The thickness alarm values (lower and upper threshold of the material thickness) can be subsequently set and changed in the AMPLECTOR Instrument Manager

Requirements

  • Operating system Windows Vista, Windows 7, Windows 8, Windows 8.1, Windows 10
  • Microsoft .NET Framework 4.5 or higher
  • Installed software AMPLECTOR Instrument Manager
  • Cable with RS-232-USB adapter for the connection between the instrument and the computer (not included in the standard package)

Standard package

  • Instrument driver software as download (no shipment on data media)
  • No Quick Start Guide necessary

Tips for the operating and use

  • The RS232-USB adapter must be set to COM 3
  • The instrument must be set to data transfer rate of 57600 baud
  • The AMPLECTOR Instrument Manager and the instrument driver can only display and edit the data and information from the instrument at the quality which was originally saved
  • The stability and quality of communication between the AMPLECTOR Instrument Manager and the instrument are based on the transmission method of the instrument manufacturer
  • AMPLECTOR Instrument Manager and the instrument driver do not support any server and remote control mode