New Waygate Krautkramer Mentor UT Phased Array Flaw Detector
PhysicalDimensions (W x H x D)295 mm x 230 mm x 60 mm (12″ x 9.4″ x 2.4″)Weight (with battery)2.9 kg (6.5 lbs)DisplaySize264 mm (10.4″) diagonalResolution1024 x 768 pixelsModeIndoor and outdoor specific color modesViewing Angle± 85˚ all directionsTouch Screen (Multi-touch)Gloved OperationYesSurfaceChemically strengthened glass, scratch resistant, chemical resistant, optically bonded to displayData StorageSolid State Hard Drive128 GBUSB StorageUSB 2.0 w included moduleData CaptureFull ASCAN capture for every CSCAN point, all settings. Recall on instrument with full analysis capabilityData Filesmemd files, CSV filesSettings FilesAll instrument settings plus position in workflowScreen CaptureJPG FormatReportPDF FormatConnectivityWi-Fi802.11 b, g, nConnectorsUSB 2.0, Ethernet, HDMIRemote CollaborationLocal Network and Internet-Enabled via InspectionWorks ConnectInspectionWorksEnabledI/OAxes2 digital quadrature encoders for X-Y axesAudibleTone, 2.7 kHzPowerInternal Battery63 WH Lithium IonExternal Battery84 WH Lithium IonPower Supply100 to 240 VAC, 47–63 Hz, 1.9 A; 12VDCBattery Life3 hrs internal, 6 hrs with external battery under typical operating conditionsComplianceMeets IATA air transport regulations with one contained installed battery and one packed external batteryEnvironmentalOperating Temperature-20C to 55 C (-4F to 131F) to MIL-STD-810G Method 501.5 & 502.5, Procedure IStorage Temperature-20C to 70C (-4F to 158F) to MIL-STD-810G Method 501.5 & 502.5, Procedure IIIngress ProtectionTested to IP65Shock4’ Transit Drop to MIL-STD-810G method 516.6, Procedure VData VisualizationUser InterfaceCustomizable with Mentor Create softwareZoomAny data view may be expanded to full screen with gestureInstructional MaterialRich Text, JPG, PNG, BMP, PDF or Video (MP4)ViewsA-SCAN, C-SCAN, C-SCAN OVERVIEW, E-SCAN, S-SCANProbe SelectionSwap between conventional and phased array on same screenEvaluation2 Gates, one can be used as interface echo gateMeasurementsAmplitudes, Depth, Distance, % Wall Loss, Thinnest Point, X and Y PositionsCalibrations Phased Array: TCG, Material Velocity, Probe Delay, Auto80, Encoder Cal, Dead Element Check Conventional: 2 Point (Material Velocity and Probe Delay)ConfigurationPhased ArrayChannels32:32 PRAperture1–32 ElementsFocal Laws1024ScanningLinear, sectorial, focusedGroupsUp to 8ConventionalChannels1Pulser (Phased Array and Conventional)PRF10 Hz to 20 kHzPulse ShapeBipolar or unipolar square waveVoltage20–150 Vpp, 0 – -75V0p; in 5 V stepsWidth (auto or manual)50–3000 nSDelay Step Increment10 nSReceiver and Digitizer (Phased Array and Conventional)Gain0–78 dB (Phased Array), 0-94 dB (Conventional); in 0.2 dB stepsTCGNumber of PointsUp to 16Slope50 dB/µSRectificationPos HW, Neg HW, Full, RFBandwidth0.5 MHz to 15 MHzDigitizing Rate62.5 MHz, up-sampled to 500 MHzDelay Step Increment2.5 nSAcquisition Range50 nS to 150 µSASCAN Compression Points512, 1024, 2048, 4096
Leave a Reply